Pricing
Your price
€ 846,50
SKU
DF.61100
Stock
5
Specifications
Standard
Cetop 7 - NG16
Max. flow
300 lpm
Check valve in
A
Cracking pressure
2 bar
Pilot ratio
1 : 13
Category
Search code
CHM7SA10
A pilot operated check valve can be used to allow free flow in one direction by raising a conical seated poppet valve, while in the opposite direction the fluid can return by means of a small piston piloted by the other line pressure (piloted side). These valves prevent that a cilinder is moving as result from external forces, also they can act like a brake function. Pilot operated check valves are available in single and double lines.
| Max. working pressure | 350 bar |
| Viscosity | 10 - 400 cSt |
| Fluid temperature | -20ᴼC till 80ᴼC |
| Ambient temperature | -20ᴼC till 50ᴼC |
| Standard | Cetop 7 - NG16 |
| Max. flow | 300 lpm |
| Check valve in | A |
| Cracking pressure | 2 bar |
| Pilot ratio | 1 : 13 |